QUATECH, INC. MPA-200/300 Card Type I/O controller Chipset/Controller Intel I/O Options Serial port Maximum DRAM N/A [Image] CONNECTIONS Purpose Location Female D-25 serial port - data CN1 communications equipment (Optional) Male D-25 serial port - CN2 data terminal equipment Note: The MPA 200 is either DCE or DTE port equipped, but not both CLOCK SPEED SELECT Speed J1 » 8MHz Pins 1 & 2 closed 6MHz Pins 2 & 3 closed INTERRUPT SHARING Setting J4 Enabled Pins 1 & 2 closed Disabled Pins 2 & 3 closed INTERRUPT SELECTION IRQ J5 J6 IR/FONT> Pins 1 & 7 closed Open IRQ3 Pins 2 & 8 closed Open IRQ4 Pins 3 & 9 closed Open IRQ5 Pins 4 & 10 closed Open INTERRUPT SELECTION IRQ J5 J6 IRQ6 Pins 5 & 11 closed Open IRQ7 Pins 6 & 12 closed Open IRQ10 Open Pins 1 & 6 closed IRQ11 Open Pins 2 & 7 closed IRQ12 Open Pins 3 & 8 closed IRQ14 Open Pins 4 & 9 closed IRQ15 Open Pins 5 & 10 closed DMA TRANSMIT CHANNEL Setting J10 Channel 1 Pins 1 & 7, 2 & 8 closed Channel 2 Pins 3 & 9, 4 & 10 closed Channel 3 Pins 5 & 11, 6 & 12 closed DMA RECEIVE CHANNEL Setting J11 Channel 1 Pins 1 & 7, 2 & 8 closed Channel 2 Pins 3 & 9, 4 & 10 closed Channel 3 Pins 5 & 11, 6 & 12 closed Note: Do not use the same channel for both DMA transmit and receive functions. Closing the same Pins on J10 and J11 will result in damage to the system. LINE DRIVER CONTROL Setting J7 Drivers and receivers always enabled Pins 1 & 2, 4 & 5 closed Drivers and receivers controlled by Pins 2 & 3, 5 & 6 closed programming register Note: Location of J7 is not specified on manufacturer documentation. SYNCA/RLEN CONFIGURATION Setting J8 SYNCA Closed RLEN Open I/O ADDRESS CONFIGURATION Address SW1 SW2 300h 1, 2, 3, 4, 5 & 6 on 1, 2, 3, 4, 5 & 6 on 240h 1, 2, 3, 4, 5, 6 & 8 1, 3, 4, 5 & 6 on on 6FC4h 1 & 4 on 3, 4 & 5 on Note:The address range for the DMM-100 is from 0 to FFFFh. The switches are a binary representation of the addresses. The switches have the following decimal values: SW1/1=8, SW1/2=4, SW1/3=2, SW1/4=1, SW1/5=8, SW1/6=4, SW1/7=2, SW1/8=1, SW2/1=8, SW2/2=4, SW2/3=2, SW2/4=1, SW2/5=8, SW2/6=4. FACTORY CONFIGURED SETTINGS Jumper Setting J2 N/A J3 N/A